<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-23 08-27-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 54 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 68 kHz 8008 0,5120
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,8 dBr 5,07 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 68 kHz MIN: 12 kHz % above 76 kHz: 0,5120 Acquired: 2025/08/23 8.26.24 Total samples: 8008 Equivalent time: 0:06:40 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,3 dBr MIN: 3,8 dBr AVE: 5,07 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/08/23 8.26.24) 08.12 08.14 08.16 08.18 08.20 08.22 08.24 08.26 0 2 4 6 Pm [dBr]